Testing capability to read/use lightning frequency & population density
|
|
datasets. Calculates lightning ignitions using the SPITFIRE
|
|
formulation and anthropogenic ignitions using the Li et al. 2012 formulation
|
|
based on human population density implemented in CTSM-CN's fire model.
|
|
|
|
Testing does not include a separate test for reading/using a successful
|
|
ignitions dataset which uses the same format and units so handling
|
|
is the same until you're in subroutine area_burnt_intensity where for
|
|
"successful ignitions" the model selects
|
|
currentSite%FDI = 1.0_r8
|
|
cloud_to_ground_strikes = 1.0_r8
|
|
while for lightning the model can use values < 1 for both.
|
|
|
|
Lara Kueppers (UC-Berkeley) has access to a "successful ignitions"
|
|
dataset for California that has not been placed in the repository of
|
|
CTSM datasets as of 2020/6/6. That dataset can be used with the
|
|
following settings:
|
|
|
|
fates_spitfire_mode = 3
|
|
stream_fldfilename_lightng = '.../data_UCB/observed/CA_monthly_ignition_number_1980-2016/ignition_1980_to_2016_monthly_20190801.nc'
|
|
stream_year_first_lightng = 1980
|
|
stream_year_last_lightng = 2016
|
|
model_year_align_lightng = 1980
|
|
|
|
where {...} = /fs/cgd/data0/slevis on izumi and /glade/work/slevis on cheyenne.
|